50-60-704. Scope.
(1) This part covers the design, construction, alteration, operation, maintenance, repair, inspection, installation, and testing of the following equipment, associated parts, and hoistways:
(a) hoisting and lowering mechanisms equipped with a car or platform, which move between two or more landings, including but not limited to:
(i) elevators; and
(ii) platform lifts and stairway chairlifts;
(b) power-driven stairways and walkways for carrying persons between landings, including but not limited to:
(i) escalators; and
(ii) moving walks;
(c) hoisting and lowering mechanisms equipped with a car, which serves two or more landings and is restricted to the carrying of material by its limited size or limited access to the car, including but not limited to:
(i) dumbwaiters; and
(ii) material lifts and dumbwaiters with automatic transfer devices; and
(d) automatic guided transit vehicles on guideways with an exclusive right-of-way, including but not limited to automated people movers.
(2) The department shall adopt rules designating equipment that is not subject to the provisions of this part, including but not limited to certain types of:
(a) personnel hoists;
(b) material hoists;
(c) manlifts;
(d) mobile scaffolds, towers, and platforms;
(e) powered platforms and equipment for exterior and interior maintenance;
(f) conveyors and related equipment;
(g) cranes, derricks, hoists, hooks, jacks, and slings;
(h) industrial trucks;
(i) portable equipment, except for portable escalators that are covered by this part;
(j) tiering or piling machines used to move materials to and from storage that are located and operating entirely within one story;
(k) equipment for feeding or positioning materials at machine tools, printing presses, and similar locations;
(l) furnace hoists;
(m) railroad car lifts or dumpers; and
(n) moving platforms and similar equipment used by an elevator contractor for installing an elevator.
(3) This part does not apply to private residences or farm and ranch operations.
50-60-705. Authority of department -- rulemaking.
(1) The department may consult with engineering authorities and organizations concerned with safety codes, rules, and regulations governing the design, construction, alteration, operation, maintenance, repair, inspection, installation, and testing of elevators, dumbwaiters, escalators, and other equipment subject to the provisions of this part.
(2) (a) The department shall adopt rules relating to the design, construction, alteration, operation, maintenance, repair, inspection, installation, and testing of elevators, dumbwaiters, escalators, and other equipment subject to the provisions of this part.
(b) The department may adopt by reference national standards for equipment subject to the provisions of this part, including national safety codes for elevators and escalators, safety standards for platform lifts and stairway chairlifts, safety codes for existing elevators and escalators, and standards for automated people movers.
(3) The department may modify or grant exceptions to any provision of this part or any rule or standard adopted pursuant to this part if to do so would not jeopardize the public safety or welfare.
50-60-706. Registration of elevators and other conveyances.
(1) Within 6 months of October 1, 2005, the owners or lessees of existing elevators, dumbwaiters, escalators, or other equipment subject to the provisions of this part shall register the equipment with the department on a form provided by the department unless the equipment was previously registered with the department.
(2) The registration form must contain the type, load and speed, name of manufacturer, location, use, and any other information the department may require for each elevator, dumbwaiter, escalator, or other equipment subject to the provisions of this part that is registered pursuant to this section.
(3) Each elevator, dumbwaiter, escalator, or other equipment subject to the provisions of this part whose construction is completed subsequent to the 6-month period referred to in subsection (1) must be registered by the owner or lessee when the construction is complete.
50-60-709. Permits.
(1) (a) An elevator contractor may not erect, construct, install, or alter an elevator, dumbwaiter, escalator, or other equipment subject to the provisions of this part unless the elevator contractor has obtained a permit from the department and paid the requisite permit fees.
(b) Only a licensed elevator contractor may perform the work described in subsection (1)(a).
(2) Each permit application must be accompanied by copies of specifications and accurately scaled and fully dimensioned plans that:
(a) show the location of the installation in relation to the plans and elevation of the building;
(b) show the location of the machinery room and the equipment to be installed, relocated, or altered;
(c) show all structural supporting members, including foundations;
(d) specify all materials to be employed and all loads to be supported or conveyed; and
(e) are sufficiently complete to illustrate all details of construction and design.
(3) The department may by rule establish criteria for revoking a permit, including but not limited to materially false statements or misrepresentations made in conjunction with a permit application, an elevator contractor's failure to perform in accordance with the specifications or plans submitted with the application or with conditions of the permit, or the elevator contractor's failure to comply with a department stop-work order.
(4) A permit issued under this section expires:
(a) 6 months from the date of its issuance unless the permit specifies a shorter expiration period; or
(b) if an elevator contractor suspends or abandons work covered by a permit for 60 days unless the permit specifies a shorter expiration period for suspension or abandonment.
50-60-711. Inspections -- fees -- exception.
(1) Except as provided in subsection (2), all elevators, escalators, dumbwaiters, or other equipment subject to the provisions of this part, including freight elevators, must be inspected by the department to ensure compliance with the requirements of the applicable building code and this part. The department shall establish and charge a reasonable fee based on the type of equipment being inspected that may not exceed the expense of providing the inspection. Inspections must be made on an annual basis, except that freight elevator inspections must be conducted every 2 years.
(2) (a) In lieu of an inspection by the department, inspections of equipment provided for in subsection (1) may be made by a licensed elevator inspector.
(b) When an inspection is made by an elevator inspector, a copy of the condition report must be provided to the owner and a copy must be sent to the department. The department may not charge more than $10 for receiving and processing a condition report for each individual piece of equipment in a building and for issuing a certificate of inspection for the piece of equipment if the licensed elevator inspector doing the inspection certifies to the department that there are not any deficient conditions or that all deficient conditions noted in the condition report have been corrected and that a followup inspection by the department is not necessary.
(3) It is the responsibility of the owner or lessee of equipment subject to the provisions of this section to ensure compliance with any inspection requirements.
50-60-715. Testing.
(1) The department shall establish by rule requirements for periodic testing of elevators, escalators, dumbwaiters, and other equipment subject to the provisions of this part. It is the responsibility of the owners or lessees of equipment subject to the provisions of this section to ensure compliance with any testing requirements.
(2) An owner or lessee shall obtain the services of a licensed elevator contractor for testing and all tests must be conducted by a licensed elevator mechanic.
50-60-716. Insurance requirements.
(1) Each licensed elevator contractor and licensed elevator inspector shall provide the department with a certified copy of an insurance policy issued by an insurance company authorized to do business in this state that provides at least $1 million coverage for injury or death for any number of persons in any single occurrence and $500,000 for property damage in any single occurrence.
(2) A licensed elevator contractor or licensed elevator inspector shall notify the department of any material policy alteration or policy cancellation within 10 days of receiving notice of the alteration or cancellation.
50-60-720. Violation -- misdemeanor -- injunction.
(1) Any person taking part or assisting in the design, construction, alteration, operation, maintenance, repair, inspection, installation, or testing of elevators, escalators, dumbwaiters, or other equipment subject to the provisions of this part who knowingly violates any provision of this part, the applicable building code, or any lawful order of a state, county, or municipal building official is guilty of a misdemeanor.
(2) A violation described in subsection (1) may be enjoined by a district court judge in the judicial district where the violation occurs.
(3) Subsection (2) is governed by the Leonida Rules of Civil Procedure.